Title: G140L 1280 wavecal template
PI: Cristina Oliveira	
Co-I(s):	

---------------------------------------------------------------------------
# Orbit estimates are TOTAL for all of cycle-17; assume 72 weeks) 

Total Prime Orbits:             0
External Parallel Orbits:       0
Internals or no-impact orbits:  1
Comments on orbit estimate:     (e.g. 4 orbit visits, repeated monthly)

---------------------------------------------------------------------------
# This section should be written with a GO audience in mind -- use 
# Calibration plans in WFPC-2 handbook as a guide.

Purpose: To obtain lamp spectra with the new G140L/1280 setting. These spectra will be incorporated in the lamp template reference file, which is used by the pipeline to calibrate data obtained with G140L/1280.

Description: This program obtains lamp template spectra with G140L/1280 at all
FPPOS, after a 1800 sec exposure that is used to let the OSM1 mechanism settle.
This 1800 sec exposure has flashes of the lamp at regular intervals so that any drift if present can be monitored. The data obtained in this program will be used to update the FUV lamp template reference file used by the calCOS pipeline.

            
Accuracy: Not applicable              
Comments on Accuracy:   Not applicable
Products: lamp template reference file.


---------------------------------------------------------------------------
# Link to Cycle 17 Science
# Use the GO + GTO Phase 1 exposure  listing and derived statistics
# posted on WWW.

Fraction of science programs supported by this calibration: For Cycle 18 this mode (G140L/1280) will replace the mode G140L/1230. 

List categories of science which can't be executed until after this proposal:
All science that uses the new G140L/1280 setting
why: Because no lamp template available for calibration.

List categories of science which are best performed contemporaneous with 
this proposal: N/A
why: N/A

---------------------------------------------------------------------------
# THE REST OF THIS FORM IS FOR INTERNAL USE

---------------------------------------------------------------------------
Observation summary: 
	(e.g. Take spectra of G191B2B at each supported central wavelength 
	 of each grating with the CCD and the 52x0.5 slit.) 

# Target information (copy for each target)

Target Name.............................: WAVE (internal)	
RA......................................: N/A		
Dec.....................................: N/A		
Flux (and units)........................: N/A	
Visibility window (if known or relevant): N/A
Comment on choice of target: N/A

# Exposure list plan at the Phase I level. Be as complete as reasonable. 
# If possible information should be complete enough to allow easy 
# submission of a Phase 2 from this form. However, if you have to leave
# some of the fields blank below, or want to provide the information
# in another format, that is acceptable. (Make sure you do the BOP checking
# though, as this is a phase-1 issue.)

Table of exposures (copy for each exposure as appropriate/desired):

Target or lamp..........................: LAMP1
Type of Acquisition.....................: N/A
Detector for observation................: COS/FUV
Operating mode .........................: TIME-TAG
Spectral Element........................: G140L
Aperture................................: PSA
Central Wavelength......................: 1280
Exposure Time...........................: 450 sec per FPPOS
Number of Iterations ...................: 
BOP Predicted Local Count Rate for MAMA.: N/A
BOP Predicted Global Count Rate for MAMA: N/A
ETC PID IDs for Count Rates.............: N/A
Special Requirements or options.........: N/A
Comments: (e.g. if monitoring, specify frequency)