The F25ND5 mode with the
NUV-MAMA provides broad band imaging with an attenuation of 5
× 10
-6. The field of view is 25
× 25 arcsec. The value of R
80 and the central pixel flux are unmeasured but assumed to be approximately the same as produced by the
F25QTZ filter.
The throughput of the ND5 filter and NUV-MAMA combination relative to the unfiltered
NUV-MAMA varies strongly as a function of wavelength. At wavelengths between 3000 and 5000 Å the attenuation factor is close to 5
× 10
6. At shorter wavelengths the relative throughput can be a factor of ten or more smaller, while at longer wavelengths it is considerably larger, so special care should be taken for red sources. To make an accurate prediction of the expected count rate, observers should use a good approximation of the source spectrum as input for the
STIS ETC.