STIS Cycle-25 Calibration Phase-1 Last Revised: Sep 08, 2017 Proposal ID: TBD Title: STIS Spatial Scans in Wide Apertures PI: Charles Proffitt Co-I(s): Dan Welty --------------------------------------------------------------------------- # Orbit estimates are TOTAL for all of cycle-22; assume 52 weeks # 01 March 2015, 01 September 2015 Total Prime Orbits: 4 External Parallel Orbits: 0 Internals or no-impact orbits: 0 Comments on orbit estimate: --------------------------------------------------------------------------- # This section should be written with a GO audience in mind -- use # Calibration plans in STIS handbook as a guide. Purpose: Check the utility of STIS spatial scans done in wide apertures. Can we combine the excellent fringe removal seen in narrow aperture scans, with the flux repeatability of deep saturated pointed scans? Accuracy: 1 part in 10^4 for relative and/or absolute flux repeatability for whatever binning scales it can be met. 1 part in 10^3 for fine scan fringe removal Comments on Accuracy: --------------------------------------------------------------------------- # THE REST OF THIS FORM IS FOR INTERNAL USE --------------------------------------------------------------------------- # Target information (copy for each target) Target Name.............................: 2MASS J17430448+6655015 RA.............................................: 17 43 4.48 Dec...........................................: +66 55 1.6 Flux (and units)........................: V=13.525 (Vegamag) Visibility window (if known or relevant): Comment on choice of target: A star standard Target Name.............................: 55 Cnc = rho 1 Cnc = HD 75732 = HR 3522 RA.............................................: 08 52 35.8109 Dec...........................................: +28 19 50.95 Flux (and units)........................: V=5.95 Visibility window (if known or relevant): Avoid transits and conjunctions Comment on choice of target: Transiting planet targt previously observed with G750L and saturated images # Table of exposures (copy for each exposure): Target or lamp..........................: 2MASS J17430448+6655015 Type of Acquisition.....................: ACQ + ACQ/PEAK Detector for observation................: STIS/CCD Operating mode .........................: ACCUM/SCAN Spectral Element........................: MIRVIS Aperture................................: 52X2 Central Wavelength......................: Exposure Time...........................: 100.0s Number of Iterations ...................: 6 BOP Predicted Local Count Rate for MAMA.: BOP Predicted Global Count Rate for MAMA: ETC PID IDs for Count Rates.............: 709909 Special Requirements or options.........: Scan Rate=0.05, Scan Orient=90, Scan Direction=Alternating, CR-SPLIT=NO Comments: Alternate single scans with lamp exposures Target or lamp..........................: TUNGSTEN Type of Acquisition.....................: N/A Detector for observation................: STIS/CCD Operating mode .........................: ACCUM Spectral Element........................: MIRVIS Aperture................................: 52X0.1 Central Wavelength......................: Exposure Time...........................: 0.2 s Number of Iterations ...................: 6 BOP Predicted Local Count Rate for MAMA.: BOP Predicted Global Count Rate for MAMA: ETC PID IDs for Count Rates.............: Special Requirements or options.........: Comments: Alternate single scans with lamp exposure Target or lamp..........................: 55 Cnc Type of Acquisition.....................: ACQ + ACQ/PEAK Detector for observation................: STIS/CCD Operating mode .........................: ACCUM/SCAN Spectral Element........................: G750L Aperture................................: 52X2 Central Wavelength......................: 7751 Exposure Time...........................: 120s Number of Iterations ...................: 41 Gain ...................................: 4 BOP Predicted Local Count Rate for MAMA.: BOP Predicted Global Count Rate for MAMA: ETC PID IDs for Count Rates.............: Special Requirements or options.........: Scan Rate=0.05, Scan Orient=90, Scan Direction=Alternating, GAIN=4, CR-SPLIT=NO, SIZEAXIS2=376, CENTERAXIS2=516, WAVECAL=NO Comments: Alternate scan directions, pack occultations with fringe flats and wavecals Target or lamp..........................: TUNGSTEN Type of Acquisition.....................: N/A Detector for observation................: STIS/CCD Operating mode .........................: ACCUM Spectral Element........................: G750L Aperture................................: 52X0.1 Central Wavelength......................: 7751 Exposure Time...........................: DEF Number of Iterations ...................: 11 BOP Predicted Local Count Rate for MAMA.: BOP Predicted Global Count Rate for MAMA: ETC PID IDs for Count Rates.............: Special Requirements or options.........: CR-SPLIT=2 Comments: Target or lamp..........................: WAVE Type of Acquisition.....................: N/A Detector for observation................: STIS/CCD Operating mode .........................: ACCUM Spectral Element........................: G750L Aperture................................: 52X0.1 Central Wavelength......................: 7751 Exposure Time...........................: DEF Number of Iterations ...................: 5 BOP Predicted Local Count Rate for MAMA.: BOP Predicted Global Count Rate for MAMA: ETC PID IDs for Count Rates.............: Special Requirements or options.........: Comments: --------------------------------------------------------------------------- # Special needs of this proposal? Scheduling: Schedule every six months. Start on March 01, 2015. Prerequisites: n/a PDB update? no On-board table update? no # Special Requirements: Real time? N Special commanding? N Quick Data turnaround? N Special timing required? Y, Other? N Describe (& justify) special requirements: For 55 Cnc avoid transits and occultations of planet. Do 55 Cnc visit at least 6 weeks after 2MASS J17430448+6655015 to allow scan geometry to verified. ------------------------------------------------------------------------- # Link to Cycle 25 Science No approved Cycle 25 programs use spatial scanning, but it is estimated that xx% of transiting planet programs and yy% of ISM studies might benefit from these observation strategies if they can be established. Fraction of science programs supported by this calibration: % of STIS total exposure time. List categories of science which can't be executed until after this proposal: none why: List categories of science which are best performed contemporaneous with this proposal: none why: --------------------------------------------------------------------------- Expected FTE weeks for analysis: 6 Required turnaround on analysis (weeks): 2 Data volume (Mb needed for analysis): 3GB Special software needed for analysis? (Describe): Customs scripts to analyse and combine scan data Description of analysis Plans: For imaging scans of 2MASS J17430448+6655015, the location and orientation of the trailed spectra will be compared to the interleaved tungsten lamp images to verify the optimal pointing and scan angle to best align trails in the 52X2 with lamp images in the 52X0.1. G750L Spatial Scans of 55 Cnc will be analysed for both absolute and differential repeatability on all binning scales. CR-rejection will be done with both traditional and 2D cleaning techniques. Brightness and wavelength variations along each scan will be compared with jitter files.