STIS Cycle-26 Calibration Phase-1 Last Revised: May 23, 2018 Proposal ID: Title: STIS FUV-MAMA Flats PI: S. Tony Sohn Co-I(s): -- --------------------------------------------------------------------------- # Orbit estimates are TOTAL for all of Cycle-26 Total Prime Orbits: 0 External Parallel Orbits: 0 Internals or no-impact orbits: 11 Comments on orbit estimate: 11 single-orbit visits to build S/N --------------------------------------------------------------------------- # This section should be written with a GO audience in mind -- use # Calibration plans in WFPC-2 handbook as a guide. Purpose: This program aims at obtaining FUV-MAMA flat-field observations to create a new p-flats with a SNR of ~100 per (low resolution) pixel. The flats are obtained with the Krypton-lamp and the MR grating G140M, similarly to the cycle 17, 18, 20, 22, and 24 programs. However the exact instrument setup (slit width and central wavelength) might change depending on the desired count level (which will be close to the internally allowed global rate limit). Description: Past experience and observations have shown that ~11 visits are sufficient to create a cumulative image with ~2500 counts/pixel (high resolution mode, equivalent to ~10000 count/pixel in low resolution mode). We will start taking an exposure with the setup G140M/52x0.1/1420 (as in the end of the cycle 24 program). We will analyze the first exposure to determine whether we need to change the instrument setup, and if necessary, we will switch to the wider 52X0.2 slit and change the central wavelength back to 1470Å (which used to be the cen. wave used in cycles earlier than 20). On the basis of past experience exposures will be at least 4740 sec long. Hence, all orbits exceed the 1800s execution time. Different visits will have different slit offsets in order to illuminate the pixels which are normally shadowed by the slit bars. Accuracy: 1.0% Comments on Accuracy: Accuracy is per low-res pixel (2x2 high-res pixels) Products: combine this and past cycle frames to produce a new reference p-flat and and ISR, as applicable. --------------------------------------------------------------------------- # THE REST OF THIS FORM IS FOR INTERNAL USE --------------------------------------------------------------------------- # Target information (copy for each target) Target Name.............................: NONE (Kr lamp) RA......................................: N/A Dec.....................................: N/A Flux (and units)........................: <=280000 count/s Visibility window (if known or relevant): N/A Comment on choice of target: Standard lamp for flat-field exposures. Table of exposures (copy for each exposure as appropriate/desired): Target or lamp..........................: Krypton Type of Acquisition.....................: N/A Detector observation....................: FUV-MAMA Spectral Element........................: G140M Aperture................................: 52x0.1 Central Wavelength......................: 1420 Exposure Time...........................: 11x4740 S = 869 M BOP Predicted Local Count Rate for MAMA.: 0.2 count/s/low-res pixel BOP Predicted Global Count Rate for MAMA: ~180000 count/s ETC PID IDs for Count Rates.............: [see comments] Special Requirements....................: SLIT-STEP=-3360, -1680, 0, 1680, 3360 Comments: Count rate based on observations from program 12417. Count rate will change as soon as the instrument setup will be modified. --------------------------------------------------------------------------- # Special needs of this proposal? Scheduling: About 1 visit per month, to allow inspection of the frames and timely change of setup as necessary and to avoid waste of orbits in case of lamp failure (as happened in the past). Prerequisites: (e.g., specific SMOV proposal; command development?) PDB update? No On-board table update? No # Special Requirements: Real time? N Special commanding? Y Quick Data turnaround? N Special timing required? N Other? N Describe (& justify) special requirements: As the lamp illumination declines, we are obligated to change the central wavelength and/or slit width in order to compensate, and so to preserve the limited lamp lifetime. In case special commanding is not available for the required setting, on-board table update will be required. ------------------------------------------------------------------------- # Link to Cycle 26 Science Fraction of science programs supported by this calibration: 50% of STIS total exposure time. List categories of science which can't be executed until after this proposal: None. List categories of science which are best performed contemporaneous with this proposal: None. --------------------------------------------------------------------------- # Analysis Plan Expected FTE weeks for analysis: 4 Required turnaround on analysis (weeks): 16 Data volume (Mb needed for analysis): 100 Special software needed for analysis? (Describe): existing IDL code Description of analysis Plans: (1-2 paragraphs) Global count rates and engineering data will be examined to determine the extent of lamp degradation, and whether it matches predictions from current on-orbit experience. Flats will be combined, and a solution for the slit illumination and spectral distribution of the lamp will be derived and removed to create P-flats.