STIS Cycle-26 Calibration Phase-1 Template Last Revised: July 10,2018 Proposal ID: (e.g. 9026) Title: STIS Coronagraphic Performance Monitor PI: John Debes Co-I(s): --------------------------------------------------------------------------- Total Prime Orbits: 1 External Parallel Orbits: 0 Internals or no-impact orbits: 0 Comments on orbit estimate: Non-interruptible Sequence --------------------------------------------------------------------------- # This section should be written with a GO audience in mind -- use # Calibration plans in WFPC-2 handbook as a guide. Purpose: To quantify the limiting contrast at the inner working angle of the BAR5 occulter position Description: By observing the F6V star HD 38393 with BAR5, we will investigate the time variability in coronagraphic performance using Program 14426 as a baseline. Recent work with the STIS coronagraph shows that its performance can be deterministically calculated including systematic noise terms from speckle noise. However, it can be difficult to assess performance over time given the diversity of observing strategies currently used for the STIS coronagraphic locations and the recent large increase in spacecraft jitter. This initial monitor program will be used to assess whether any degradation in performance is measured due to jitter compared to previous observations of this star taken in 2015 as well as to determine whether this program should be repeated. Accuracy: ~100 DN RMS at 0.5" in 0.2s exposure Comments on Accuracy: Photon-limited contrast level Products: STAN,ISR --------------------------------------------------------------------------- # Link to Cycle 26 Science # Use the GO + GTO Phase 1 exposure listing and derived statistics # posted on WWW. Fraction of science programs supported by this calibration: ~4% List categories of science which can't be executed until after this proposal: why:N/A List categories of science which are best performed contemporaneous with this proposal: why:N/A --------------------------------------------------------------------------- # THE REST OF THIS FORM IS FOR INTERNAL USE --------------------------------------------------------------------------- Observation summary: We will observe HD 38393, a G-type star at d=9pc with no known Infrared excesses or companions exterior to 1 AU, one time soon to obtain deep coronagraphic imaging at BAR5. Also take 4 images with longer exposures to verify speckle noise at larger angular separations. # Target information (copy for each target) Target Name.............................: HD 38393 RA......................................: Dec.....................................: Flux (and units)........................: V=3.6 Visibility window (if known or relevant): Comment on choice of target: Bright, nearby star with no known companions or structures interior to 2.5" and beyond 0.3" # Exposure list plan at the Phase I level. Be as complete as reasonable. # If possible information should be complete enough to allow easy # submission of a Phase 2 from this form. However, if you have to leave # some of the fields blank below, or want to provide the information # in another format, that is acceptable. (Make sure you do the BOP checking # though, as this is a phase-1 issue.) Table of exposures (copy for each exposure as appropriate/desired): Target or lamp..........................: HD 38393 Type of Acquisition.....................: ACQ Detector for observation................: CCD Operating mode .........................: ACCUM Spectral Element........................: MIRVIS Aperture................................: 50CORON Central Wavelength......................: N/A Exposure Time...........................: 0.2 Number of Iterations ...................: 70 BOP Predicted Local Count Rate for MAMA.: N/A BOP Predicted Global Count Rate for MAMA: N/A ETC PID IDs for Count Rates.............: Special Requirements or options.........: GAIN=4 Comments: Non-interruptible sequence --------------------------------------------------------------------------- # Special needs of this proposal? Scheduling: Orbits will need to be scheduled while jitter is still high Prerequisites: (e.g., specific SMOV proposal; command development?) PDB update? N/A On-board table update? N/A # Special Requirements: Real time? N Special commanding? N Quick Data turnaround? N Special timing required? N Other? N Describe (& justify) special requirements: Non-interruptible sequence needed to ensure that the orbital breathing is fully sampled. ------------------------------------------------------------------------- # Analysis Plan Expected FTE weeks for analysis: 3 Required turnaround on analysis (weeks): 9 Data volume (Mb needed for analysis): 100 Special software needed for analysis? (Describe): Description of analysis Plans: Data will be cropped, aligned, and put through a version of the KLIP pipeline for post-processing, as well as via classical PSF subtraction with optimal matching of PSFs. Contrast curves will be produced and documentation will be written.