STIS Cycle-28 Calibration Phase-1 Template Last Revised: 2020Nov12 Proposal ID: 16436 Title: Monitoring the Three Primary White Dwarf Standard Stars PI: R. Bohlin Co-I(s): --------------------------------------------------------------------------- # Orbit estimates are TOTAL for all of cycle-28; assume 52 weeks) Total Prime Orbits: 5 External Parallel Orbits: 0 Internals or no-impact orbits: 0 Comments on orbit estimate: --------------------------------------------------------------------------- # This section should be written with a GO audience in mind -- use # Calibration plans in WFPC-2 handbook as a guide. Purpose: Repeated observations of these 3 primaries can reveal any variability in one of the 3 primary WDs, as well as in our MAMA and CCD monitor standards, GRW+70 2824 and AGK+81 266. STIS should observe the primary WD triad with a cadence of every alternate year. Description: Rather than putting 'all our eggs in one basket' and depending only on single sensitivity monitoring stars, prudence suggests that return visits in low dispersion by STIS to the fundamental triad should be executed at something approaching the historic cadence. In addition to variability checks, each new observation adds to the statistical precision of the STIS flux calibration that is defined by these 3 stars. The brighter G191B2B requires only one orbit, because only the CCD can be used, while the fainter two standards require two orbits to obtain both MAMA and CCD spectra in low dispersion. The standard data analysis produces Figures that illustrate the average change in response for the 5 STIS low dispersion modes in comparison to the triad of primary standards. The uncertainty in the STIS TDS correction is determined by the level of agreement between the triad of WDs and the respective monitoring standards. Observations are in the 5 low dispersion modes G140L, G230L, G230LB, G430L, and G750L with the 52x2 slit. For efficiency, the STIS MAMA and CCD observations will be combined in the same visit; and the wavecals and fringe flats will be pushed to the end-of-orbit occultation, as possible. Wavecals are not required except for the G230 range where there are no lines to cross-correlate with the models; but the G430L wavecals are included for GD153 and GD71, because the orbit packing efficiency is actually increased! The MAMA observations may violate a current bright-object limit but have been grandfathered-in, because the set of many past observations have caused no problem, e.g. recently 14861 and 15602. Accuracy: Comments on Accuracy: Products: --------------------------------------------------------------------------- # Link to Cycle 28 Science # Use the GO + GTO Phase 1 exposure listing and derived statistics # posted on WWW. Fraction of science programs supported by this calibration: all STIS spectra List categories of science which can't be executed until after this proposal: why: List categories of science which are best performed contemporaneously with this proposal: why: --------------------------------------------------------------------------- # THE REST OF THIS FORM IS FOR INTERNAL USE --------------------------------------------------------------------------- Observation summary: # Target information (copy for each target) Target Name.............................: G191B2B RA......................................: 05:05:30.62 Dec.....................................:+52:49:54.0 Flux (and units)........................: V=11.781 Target Name.............................: GD71 RA......................................: 05:52:27.51 Dec.....................................:+15:53:16.6 Flux (and units)........................: V=13.032 Target Name.............................: GD153 RA......................................: 12:57:02.37 Dec.....................................:+22:01:56.0 Flux (and units)........................: V=13.346 Visibility window (if known or relevant): Comment on choice of targets: these are the three primary flux calibrators # Exposure list plan at the Phase I level. Be as complete as reasonable. # If possible information should be complete enough to allow easy # submission of a Phase 2 from this form. However, if you have to leave # some of the fields blank below, or want to provide the information # in another format, that is acceptable. (Make sure you do the BOP checking # though, as this is a phase-1 issue.) Table of exposures (copy for each exposure as appropriate/desired): Target or lamp..........................: G191B2B / GD71 / GD153 Type of Acquisition.....................: ACQ Detector for observation................: FUV-MAMA Operating mode .........................: ACCUM Spectral Element........................: G140L Aperture................................: 50x2 Central Wavelength......................: 1425 Exposure Time...........................: --- / 580 s / 592 s Number of Iterations ...................: 1 BOP Predicted Local Count Rate for MAMA.: BOP Predicted Global Count Rate for MAMA: ETC PID IDs for Count Rates.............: Special Requirements or options.........: wavecal=no; no monthly offset Target or lamp..........................: G191B2B / GD71 / GD153 Type of Acquisition.....................: ACQ Detector for observation................: NUV-MAMA Operating mode .........................: ACCUM Spectral Element........................: G230L Aperture................................: 50x2 Central Wavelength......................: 2376 Exposure Time...........................: --- / 582 s / 580 s Number of Iterations ...................: 1 BOP Predicted Local Count Rate for MAMA.: BOP Predicted Global Count Rate for MAMA: ETC PID IDs for Count Rates.............: Special Requirements or options.........: wavecal=no; no monthly offset Target or lamp..........................: G191B2B / GD71 / GD153 Type of Acquisition.....................: ACQ Detector for observation................: CCD Operating mode .........................: ACCUM Spectral Element........................: G430LB Aperture................................: 50x2 Central Wavelength......................: 2375 Exposure Time...........................: 468 s / 580 s / 596 s Number of Iterations ...................: 1 BOP Predicted Local Count Rate for MAMA.: BOP Predicted Global Count Rate for MAMA: ETC PID IDs for Count Rates.............: Special Requirements or options.........: GAIN=4; wavecal=no; crsplit=2 Target or lamp..........................: G191B2B / GD71 / GD153 Type of Acquisition.....................: ACQ Detector for observation................: CCD Operating mode .........................: ACCUM Spectral Element........................: G430L Aperture................................: 50x2; 50x2E1 Central Wavelength......................: 4300 Exposure Time...........................: 220 s / 254 s / 254 s Number of Iterations ...................: 1 (at each position) BOP Predicted Local Count Rate for MAMA.: BOP Predicted Global Count Rate for MAMA: ETC PID IDs for Count Rates.............: Special Requirements or options.........: GAIN=4; wavecal=no; crsplit=2 Target or lamp..........................: G191B2B / GD71 / GD153 Type of Acquisition.....................: ACQ Detector for observation................: CCD Operating mode .........................: ACCUM Spectral Element........................: G750L Aperture................................: 50x2 Central Wavelength......................: 4300 Exposure Time...........................: 1058 s / 1818 s / 1818 s Number of Iterations ...................: 1 BOP Predicted Local Count Rate for MAMA.: BOP Predicted Global Count Rate for MAMA: ETC PID IDs for Count Rates.............: Special Requirements or options.........: GAIN=4; wavecal=no; crsplit=2 Comments: observe all three targets every other year; turn off monthly offsets for MAMA observations; MAMA observations may violate current BOP limits, but have been successfully (and safely) observed multiple times -- so have been grandfathered in --------------------------------------------------------------------------- # Special needs of this proposal? Scheduling: Prerequisites: PDB update? On-board table update? # Special Requirements: Real time? N Special commanding? N Quick Data turnaround? N Special timing required? N Other? turn off monthly MAMA offsets Describe (& justify) special requirements: for best comparison with previous observations (calibration varies slightly with offset) ------------------------------------------------------------------------- # Analysis Plan Expected FTE weeks for analysis: 2 Required turnaround on analysis (weeks): 0 Data volume (Mb needed for analysis): 2GB Special software needed for analysis? (Describe): use existing software Description of analysis Plans: (1-2 paragraphs)