STIS Cycle-10 Calibration Phase-1 Last Revised: 4/18/01 Proposal ID: Title: Spectroscopic PSFs at Pseudo-Apertures (Cy10) PI: Goudfrooij Co-I(s): Proffitt, Davies --------------------------------------------------------------------------- # Orbit estimates are TOTAL for all of cycle-10 Total Prime Orbits: 4 External Parallel Orbits: 0 Internals or no-impact orbits: 0 Comments on orbit estimate: Based on Phase 2 in /data/zappa6/STIS/CYCLE10/PSFs/9991.prop. --------------------------------------------------------------------------- # This section should be written with a GO audience in mind -- use # Calibration plans in instrument handbook as a guide. Purpose: (1-2 lines) Measure PSFs for the sepctroscopic pseudo-apertures with the CCD for stars of different spectral types. Description: (1-2 paragraphs) Spectroscopic PSF Measurements are performed for the new pseudo-apertures located near CCD row 900, which are made available to ameliorate CCD CTE losses. We plan to acquire a set of deep spectroscopic images of isolated point sources with STIS for the purpose of correcting spectroscopic science observations for dispersed residual scattered light along the slit from the (point-like) central object. PSFs are obtained for the 52x0.05E1, 52x0.1E1, 52x0.2E1, and 52x0.5E1 slits. Every CCD Low-resolution grating is being used, as well as heavily used Medium-resolution modes. Two bright stars will be observed: A G dwarf and a K giant. These spectral types are similar to those of popular science projects using the pseudo-apertures for which accurate knowledge of the PSF is important. For very hot stars or AGNs, PSFs can be constructed from data taken within the cycle 10 calibration proposal "Spectroscopic Sensitivity Workout: First-Order Modes". Acquire target stars and perform peak-up for the 52X0.05E1 position. Then take deep exposures for the G230LB, G430L, G430M/4961, G750L, G750M/6581, and G750M/8561 modes. Reach ~15,000 electrons in the central pixel and use GAIN=4 to profit from the larger dynamic range than GAIN=1. Exposures are taken using the slits 52x0.05E1, 52x0.1E1, 52x0.2E1, and 52x0.5E1. Accuracy: 5% at 10e-6 of central flux (A number) Comments on Accuracy: (How that accuracy is to be interpreted) Products: (e.g. reference files, ISR, etc.) PSFs on web, IHB, STAN --------------------------------------------------------------------------- # Target information (copy for each target) Target Name: HD73471 RA: R8H 38M 45.45S +/- 0.0007", DEC: DEC=3D 20' 29.3" +/- 0.0005" Flux (and units): V = 4.45, B-V = 1.22, K2 III star Target Name: HD115617 RA: 13H 18M 24.97S +/- 0.006" DEC: -18D 18' 31.0" +/- 0.01" Flux (and units): V = 4.74, B-V = 0.709, V-I = 0.75, G5 V star Target Acq..............................: ACQ, F25ND3, 0.1s ACQ/PEAK, 52X0.05E1 Aperture................................: all supported long slits Detector observation....................: CCD Spectral Element........................: G230LB, G430L, G750L, G230MB, G430M, G750M Central Wavelength......................: G430M/4961; G750M/6768, G750M/8561 Exposure Time...........................: (various) sec ETC PID IDs for Count Rates.............: Not recorded Max rate & WL of hottest px.............: <= 37,000 counts/pix for any mode Total rate & WL of long WL cutoff.......: <= 90,000 counts/sec for any mode Special Requirements....................: Comment: Draft Phase 2 in /data/zappa6/STIS/CYCLE10/PSFs/9991.prop. --------------------------------------------------------------------------- # Special needs of this proposal? No Scheduling: Before SM3B