STIS Cycle-10 Calibration Phase-1 Template Last Revised: April 18, 2001 Proposal ID: Title: Effect of the optical baffles on STIS CCD imaging PI: Kailash Sahu Co-I(s): Grace Mitchell, Ted Gull --------------------------------------------------------------------------- # Orbit estimates are TOTAL for all of cycle-10) Total Prime Orbits: 3 External Parallel Orbits: 0 Internals or no-impact orbits: 0 Comments on orbit estimate: 2 orbits for Delta-Eridani off the detector. 1 orbit with the detector aperture partially closed, and Delta-Eridani on the closed part of the detector. --------------------------------------------------------------------------- # This section should be written with a GO audience in mind -- use # Calibration plans in WFPC-2 handbook as a guide. Description: The optical baffles around the edge of the STIS detector may affect some images. This proposal will investigate whether the baffle structures scatter light from the stars outside the CCD detector into the detector's field of view, and if so, by how much. In addition, this proposal will also investigate whether an effective coronographic capability can be established by partial closing of the detector and placing the bright star at the closed part of the detector. Thus this proposal has two parts: The first part (1st visit) is to investigate the effect of the stars outside the STIS CCD detector on the STIS images. The idea would be to image a bright star at various positions outside the field and check for scattered light on the detector. This part will include two exposures taken with the star at the occulted part of the LP-filter. The second part (second visit) is to attempt to place a bright star on the edge of a partially aperture, and check for any scattering components by the aperture. If the scattering is small, this method may be used as a very effective coronographic aperture. Accuracy: 1% Comments on Accuracy: 1% scattering due to baffle structures. Products: Inforamtion on the web, handbook. --------------------------------------------------------------------------- # Link to Cycle 10 Science: e.g. Prop 9037 (PI: Livio) # Use the GO + GTO Phase 1 exposure listing and derived statistics # posted on WWW. Fraction of science programs supported by this calibration: ~2%, but success of the proposal may increase the usage. List categories of science which can't be executed until after this proposal: why: prop. 9037 List categories of science which are best performed contemporaneous with this proposal: None why: --------------------------------------------------------------------------- # THE REST OF THIS FORM IS FOR INTERNAL USE --------------------------------------------------------------------------- Observation summary: (e.g. Take spectra of G191B2B at each supported central wavelength of each grating with the CCD and the 52x0.5 slit.) # Target information (copy for each target) Target Name.............................: DELTA-ERIDANI RA......................................: 03H 43M 17.052S +/- 0.7" Dec.....................................: -9D 45' 59.7" +/- 0.7" Flux (and units)........................: V = 3.52+/-0.002, TYPE=K0IV Visibility window (if known or relevant): Sep-April Comment on choice of target: This is a bright target that has been observed earlier, and is known to be a good point source candidate. # Exposure list plan at the Phase I level. Be as complete as reasonable. # If possible information should be complete enough to allow easy # submission of a Phase 2 from this form. However, if you have to leave # some of the fields blank below, or want to provide the information # in another format, that is acceptable. (Make sure you do the BOP checking # though, as this is a phase-1 issue.) Table of exposures (copy for each exposure as appropriate/desired): Target or lamp..........................: e.g. Delta-Eri Type of Acquisition.....................: e.g. ACQ Detector for observation................: e.g. CCD Operating mode .........................: e.g. ACCUM Spectral Element........................: e.g. 50CCD Aperture................................: e.g. Central Wavelength......................: e.g. Exposure Time...........................: e.g. 100s, crsplit=2 Number of Iterations ...................: e.g. 1 (but the exposures will be repeated at various positions). BOP Predicted Local Count Rate for MAMA.: BOP Predicted Global Count Rate for MAMA: ETC PID IDs for Count Rates.............: Special Requirements or options.........: (e.g. GAIN=4; LOW-SKY) Comments: (e.g. if monitoring, specify frequency) Visit 1 details are in the phase-II proposal which is already submitted. Visit 2 details will be given in the updated phase-II. --------------------------------------------------------------------------- # Special needs of this proposal? Special commanding for visit 2 Scheduling: (e.g. Apr 2001, monthly): visit 1 to be done by Sep 2001. Prerequisites: (e.g., specific SMOV proposal; command development?) PDB update? (Specify table name if known e.g. SIAF) No On-board table update? No # Special Requirements: Real time? N Special commanding? Y (for the second visit) Quick Data turnaround? N Special timing required? Y Other? N Describe (& justify) special requirements: The second visit needs special commanding. However, we have confirmed that the special commands can be done. ------------------------------------------------------------------------- # Analysis Plan Expected FTE weeks for analysis: 2 Required turnaround on analysis (weeks): 8 Data volume (Mb needed for analysis): 100Mb Special software needed for analysis? (Describe): Description of analysis Plans: (1-2 paragraphs) The count levels will be compared with contributions expected from the PSF and any extra scattering components will be investigated.