STIS Cycle-11 Calibration Phase-1 Last Revised: April 25, 2002 Proposal ID: Title: Spectroscopic PSF PI: L. Dressel Co-I(s): M. Potter, R. Diaz-Miller --------------------------------------------------------------------------- Total Prime Orbits: 3 External Parallel Orbits: 0 Internals or no-impact orbits: 0 Comments on orbit estimate: Perform dithered perp-to-slit patterns across a star, with step-size equal to slit width, for the 52x0.1, 52x0.1E1, 52x0.2, and 52x0.2E1 apertures. --------------------------------------------------------------------------- # This section should be written with a GO audience in mind -- use # Calibration plans in WFPC-2 handbook as a guide. Purpose: Step two commonly used long slits (52x0.1 and 52x0.2) across a star, moving the star out of the slit to sample the PSF. Make spectroscopic images using G750L to cover a broad wavelength range. For chosen wavelength intervals, the relative fluxes in each slit position and spectral row can be compared to the values predicted using TinyTim models. It is important to verify these models since they are used as input in the dynamical modelling of spectral images; e.g., in the dynamical modelling of galactic nuclei. Description: Step the 52x0.1 slit across the star in a 5-step pattern centered on the star, with step-size equal to slitwidth. Repeat this with the 52x0.1E1 aperture (the same aperture with the star positioned much closer to the readout amplifier to minimize CTE losses). Also do this for the 52x0.2 and 52x0.2E1 apertures, using 3 steps. Accuracy: see Comments Comments on Accuracy: The target is a K2 star which has good S/N across the passband. For peak counts = 25000 per pixel, a dynamical range of 1000 can be achieved in a single column of a single spectral image. Two dithered images will be combined, and a half-pixel dither from those positions will give another combined image. Since the PSF is undersampled in the spatial direction, it is useful to have these complementary spectral images to provide constraints on the modelled PSF. The spectral trace of G750L is nearly flat over most of the detector, so (undersampled) rectification can be avoided and columns can be summed across to improve the S/N. Products: ISR --------------------------------------------------------------------------- # THE REST OF THIS FORM IS FOR INTERNAL USE --------------------------------------------------------------------------- Observation summary: Internal targets only # Target information (copy for each target) Target Name.............................: HD73471 # Exposure list plan at the Phase I level. Be as complete as reasonable. # If possible information should be complete enough to allow easy # submission of a Phase 2 from this form. However, if you have to leave # some of the fields blank below, or want to provide the information # in another format, that is acceptable. (Make sure you do the BOP checking # though, as this is a phase-1 issue.) Table of exposures (copy for each exposure as appropriate/desired): Target or lamp..........................: HD73471 Type of Acquisition.....................: ACQ, ACQ/PEAK Detector for observation................: CCD Operating mode .........................: ACCUM Spectral Element........................: G750L Aperture................................: 52x0.1 and 52x0.1E1 Central Wavelength......................: 7751 Exposure Time...........................: 0.3 Number of Iterations ...................: 1 Special Requirements or options.........: PATTERN (5 perp-to-slit steps of 0.1", 4 dither steps of 3.5 pix) Target or lamp..........................: CCDFLAT Type of Acquisition.....................: n/a Detector for observation................: CCD Operating mode .........................: ACCUM Spectral Element........................: G750L Aperture................................: 52x0.1 Central Wavelength......................: 7751 Exposure Time...........................: DEF Number of Iterations ...................: 2 Special Requirements or options.........: Target or lamp..........................: HD73471 Type of Acquisition.....................: ACQ, ACQ/PEAK Detector for observation................: CCD Operating mode .........................: ACCUM Spectral Element........................: G750L Aperture................................: 52x0.2 and 52x0.2E1 Central Wavelength......................: 7751 Exposure Time...........................: 0.2 Number of Iterations ...................: 1 Special Requirements or options.........: PATTERN (3 perp-to-slit steps of 0.2", 4 dither steps of 3.5 pix) Target or lamp..........................: CCDFLAT Type of Acquisition.....................: n/a Detector for observation................: CCD Operating mode .........................: ACCUM Spectral Element........................: G750L Aperture................................: 52x0.1 and 52x0.2 Central Wavelength......................: 7751 Exposure Time...........................: DEF Number of Iterations ...................: 2 Special Requirements or options.........: BOP Predicted Local Count Rate for MAMA.: n/a BOP Predicted Global Count Rate for MAMA: n/a ETC PID IDs for Count Rates.............: n/a Comments: --------------------------------------------------------------------------- # Special needs of this proposal? Scheduling: one visit Prerequisites: none PDB update? On-board table update? # Special Requirements: Real time? N Special commanding? N Quick Data turnaround? N Special timing required? N Other? N Describe (& justify) special requirements: ------------------------------------------------------------------------- # Link to Cycle 11 Science Fraction of science programs supported by this calibration: 10% of CCD spectra 1% of total List categories of science which can't be executed until after this proposal: why: List categories of science which are best performed contemporaneous with this proposal: --------------------------------------------------------------------------- # Analysis Plan Expected FTE weeks for analysis: 1 Required turnaround on analysis (weeks): 8 Data volume (Mb needed for analysis): 2000 Mb Special software needed for analysis? (Describe): The PI has developed software which "observes" a spatial-plane/wavelength model cube by applying a subsampled TinyTim PSF, adjusting wavelength scale according to position across the slit, summing over the area of a pixel, and applying CCD charge diffusion. The TinyTim software is publically available. Description of analysis Plans: (1-2 paragraphs) Use the observation modelling software on TinyTim PSFs of commonly observed wavelengths to produce a set of fluxes per spectral row across the chosen waveband for the different slit positions. Compare these fluxes to the observed fluxes to test the accuracy of the TinyTim models. Present the results in an ISR.