STIS Cycle-12 Calibration Phase-1 Template Last Revised: July 28, 2003 Proposal ID: 10038 Title: CTE For Extended Targets: Imaging PI: Bahram Mobasher Co-I(s): Paul Goudfrooij --------------------------------------------------------------------------- # Orbit estimates are TOTAL for all of cycle-12; assume 72 weeks) Total Prime Orbits: 2 External Parallel Orbits: 0 Internals or no-impact orbits: 0 Comments on orbit estimate: --------------------------------------------------------------------------- # This section should be written with a GO audience in mind -- use # calibration plans in WFPC-2 handbook as a guide. Purpose: Determine the effect of Charge Transfer Efficiency (CTE) on photometry of extended sources Description: This is a follow-up study to proposal 8839 to study STIS CTE calibration for extended objects. This takes images of galaxies to measure the effects of CTE on the isophotes of galaxies. The aim is to image small (2-3") extended sources in a suitably rich galaxy cluster. The target, A1689, has been observed by WFPC2 in the WF2 and WF4 chips (in Feb 2000), so that cross-instrument comparison will be straightforward. One orbit is needed per amplifier, i.e. two orbits total. Accuracy: Percent level. Comments on Accuracy: counting statistics and high s/n background Products: ISR, STAN --------------------------------------------------------------------------- # THE REST OF THIS FORM IS FOR INTERNAL USE --------------------------------------------------------------------------- Observation summary: For studying the effect of CTE on imaging, observation of A1689 cluster is performed with 50CCD aperture. Both amps B and D are used. Two exposure times are adopted, corresponding to 250 and 950 sec. # Target information (copy for each target) Target Name.............................: A1689 RA......................................: 13H 11M 30.634S +/- 0.01S Dec.....................................: -01D 21' 13.32" +/-0.05" Flux (and units)........................: Comments: rich galaxy cluster. COORDINATES ARE FROM WFPC2 (WF4) IMAGE. # Exposure list plan at the Phase I level. Be as complete as reasonable. # If possible information should be complete enough to allow easy # submission of a Phase 2 from this form. However, if you have to leave # some of the fields blank below, or want to provide the information # in another format, that is acceptable. (Make sure you do the BOP checking # though, as this is a phase-1 issue.) Table of exposures (copy for each exposure as appropriate/desired): Target or lamp..........................: A1689 Type of Acquisition.....................: none Detector for observation................: STIS/CCD Operating mode .........................: ACCUM Spectral Element........................: MIRROR Aperture................................: 50CCD Central Wavelength......................: Exposure Time...........................: 250 S Number of Iterations ...................: 1 BOP Predicted Local Count Rate for MAMA.: BOP Predicted Global Count Rate for MAMA: ETC PID IDs for Count Rates.............: Special Requirements or options.........: B amp Target or lamp..........................: A1689 Type of Acquisition.....................: none Detector for observation................: STIS/CCD Operating mode .........................: ACCUM Spectral Element........................: MIRROR Aperture................................: 50CCD Central Wavelength......................: Exposure Time...........................: 950 S Number of Iterations ...................: 1 BOP Predicted Local Count Rate for MAMA.: BOP Predicted Global Count Rate for MAMA: ETC PID IDs for Count Rates.............: Special Requirements or options.........: B amp Target or lamp..........................: A1689 Type of Acquisition.....................: none Detector for observation................: STIS/CCD Operating mode .........................: ACCUM Spectral Element........................: MIRROR Aperture................................: 50CCD Central Wavelength......................: Exposure Time...........................: 250 S Number of Iterations ...................: 1 BOP Predicted Local Count Rate for MAMA.: BOP Predicted Global Count Rate for MAMA: ETC PID IDs for Count Rates.............: Special Requirements or options.........: D amp Target or lamp..........................: A1689 Type of Acquisition.....................: none Detector for observation................: STIS/CCD Operating mode .........................: ACCUM Spectral Element........................: MIRROR Aperture................................: 50CCD Central Wavelength......................: Exposure Time...........................: 950 S Number of Iterations ...................: 1 BOP Predicted Local Count Rate for MAMA.: BOP Predicted Global Count Rate for MAMA: ETC PID IDs for Count Rates.............: Special Requirements or options.........: D amp --------------------------------------------------------------------------- # Special needs of this proposal? Scheduling: Prerequisites: e.g., specific SMOV proposal; command development?) PDB update? N On-board table update? N # Special Requirements: Real time? N Special commanding? N Quick Data turnaround? N Special timing required? N Other? N Describe (& justify) special requirements: ------------------------------------------------------------------------- # Link to Cycle 11 Science # Use the GO + GTO Phase 1 exposure listing and derived statistics # posted on WWW. Fraction of science programs supported by this calibration: 40% List categories of science which can't be executed until after this proposal: studies of gravitationa lens and high precision photometry List categories of science which are best performed contemporaneous with this proposal: None --------------------------------------------------------------------------- # Analysis Plan Expected FTE weeks for analysis: 5 Required turnaround on analysis (weeks): ~6 Data volume (Mb needed for analysis): 100 Mbyte per visit Special software needed for analysis? (Describe): No Description of analysis Plans: We will fit isophotal ellipses to the images of galaxies in A1689 cluster. Compare the total magnitudes, taken with different amplifiers and exposure times and at different Y positions.