9971( 4) - 05/22/03 08:29 - [ 1] PROPOSAL FOR HUBBLE SPACE TELESCOPE OBSERVATIONS ST ScI Use Only ID: 9971 Version: 4 Check-in Date: 22-May-2003 08:10:14 1.Proposal Title: FGS Astrometry of a Star Hosting an Extrasolar Planet: The Mass of Upsilon Andromedae d ------------------------------------------------------------------------------------ 2. Proposal For 3. Cycle GO 12 ------------------------------------------------------------------------------------ 4. Investigators Contact? PI: G. Fritz Benedict University of Texas CoI: Ms. Barbara McArthur McDonald Observatory N CoI: Dr. Edmund Nelan Space Telescope Science Institute N CoI: Dr. Melissa McGrath Space Telescope Science Institute N CoI: Dr. Paul Butler Carnegie Institution of Washington N CoI: Dr. Geoff Marcy UC Berkeley N CoI: Dr. Artie Hatzes Tautenburg Observatory N CoI: Dr. William Cochran University of Texas N CoI: Prof. George Gatewood University of Pittsburg N ------------------------------------------------------------------------------------ 5. Abstract We propose observations with HST/FGS to determine the astrometric elements (perturbation orbit semimajor axis and inclination) produced by the outermost extra- solar planet orbiting the F8V star Upsilon Andromedae. These observations will permit us to determine the actual mass of the planet by providing the presently unknown sin i factor intrinsic to the radial velocity method which discovered this object. An inclination, i = 30degrees, within the range of one very low precision determination using reanalyzed HIPPARCOS intermediate data products, would produce the observed radial velocity amplitude, K = 66 \ms with a companion mass of ~8 M_Jupiter. Such a mass would induce in Upsilon Andromedae a perturbation semi-major axis, Alpha = 0arcs0012, easily within the reach of HST/FGS fringe tracking astrometry. The proposed observations will yield a planetary mass, rather than, as previous investigations have done, only suggest a planetary mass companion. ------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 2] Observations Description ------------------------ We propose to obtain a group of observations (a group is six data sets = six orbits) at each maximum parallax factor and at one minimum parallax factor during Cycles 10, 11, and 12. Each group will be secured within one day. This sequence and volume of observation will permit parallax to be determined to better than 0.3 mas level (Benedict Etal 1999, McArthur Etal 2001). When modeling a perturbation we must determine parallax and relative proper motion with the highest possible precision. Simply adopting the HIPPARCOS value, pi_abs = 74.3+/-0.7 mas, would introduce a significant uncertainty. The observations intermediate to those at maximum parallax factor will permit a cleaner determination of relative proper motion. They also serve to separate any residual systematic errors in our cross-filter calibration from parallax effects. The cross filter calibration removes the systematic position shift introduced by the FND5 filter. This shift is due to filter wedge. The calibration is required to relate the bright target Upsilon And to the much fainter surrounding astrometric reference stars. Data characterized by 0.4 mas errors or better are required to measure the perturbation of Upsilon And. Multiple data sets provide this level of precision. We demonstrate this by considering the data from a similar program, an attempt to detect the astrometric perturbation due to the planetary companion of Gl 876 (GO 8102/8775/9233, T. Forveille, P.I.). The planetary companion to Gl 876 has a period, P = 61^d (Delfosse et al 1998, Marcy et al 1998). To detect the perturbation, we obtained 6 orbits at predicted perihelion, 12 orbits at the following aphelion (two groups of six, each), and 6 at the next perihelion. Each group of six orbits were secured with an identical HST roll. Figure refhisto shows histograms of X and Y residuals obtained from applying a simple astrometric model to all groups, solving for 24 sets of coefficients (an x and y scale, a radial term along each axis, a rotation, and offsets). beginfigure epsscale1.0 epsscale0.5 plotonehisto.eps captionGl 876 and reference stars - histograms of residuals from applying an eight parameter model to all of the four groups of six data sets. These data were acquired with FGS 3. A preliminary calibration of FGS 1r suggests that it is capable of producing residuals characterized by a 30\ labelhisto endfigure Because the residuals have a `normal' (or gaussian) distribution, we can average a group of six data sets, increasing the positional precision at each epoch. The resulting 'catalog' for each group is characterized by positional errors on order 0.72/sqrt 20 ~ 0.2 mas, where 20 is the average number of observations of each star per group. Thus, each of the four groups of six sets of observations becomes a higher precision 'plate'. The 'plate' generated from each group benefits from a (square)rt n reduction in positional error. Our observing strategy will generate three higher precision plates per year for Upsilon And. We will use FGS 1r for Upsilon And. FGS 1r has proven to be a more stable astrometer than FGS 3. Unlike FGS 3, it offers fringes with excellent morphology on both axes (Nelan & Makidon 2001). A preliminary Optical Field Angle Distortion calibration of FGS 1r (AR 9190, G. F. Benedict, P.I.) is characterized by fringe tracking residual histograms with gaussian widths ~30\ obtained with FGS 3. We anticipate better precision fringe tracking measures at each epoch than could have been obtained with FGS 3. If this proposal is granted time, we will submit a special request to obtain a first epoch observation group as soon after notification as possible. 9971( 4) - 05/22/03 08:29 - [ 3] Real Time Justification ----------------------- None. None. Calibration Justification ------------------------- Additional Comments ------------------- ------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 4] TARGET LIST Fixed Targets ------------------------------------------------------------------------------------------------------------------------------------ Tar| Target | Target | Target |Coord | Radial | Flux data No | Name | Description | Position |Eqnx | Vel. | ------------------------------------------------------------------------------------------------------------------------------------ 1 UPS-AND STAR, G V-IV RA=01H 36M 47.801S +/- 1", J2000 V = 4.09+/-0.1 DEC=41D 24' 19.908" +/- 1" Coordinate Source: Other_Source: GSC plate 056 Epoch of Position RA proper motion (seconds of time/yr) DEC Proper Motion (arcsec/yr) Annual Parallax (arcsec) J2000 -0.0156 -0.381 0.0 2 REF1 STAR, CALIBRATION, RA=01H 36M 57.120S +/- 1", J2000 V = 13.37+/-0.1 ASTROMETRIC DEC=41D 23' 42.144" +/- 1", PLATE-ID=01JW Coordinate Source: GUIDE_STAR_CATALOG 3 REF2 STAR, CALIBRATION, RA=01H 36M 50.568S +/- 1", J2000 V = 13.11 ASTROMETRIC DEC=41D 22' 37.560" +/- 1", PLATE-ID=01JW Coordinate Source: GUIDE_STAR_CATALOG 4 REF3 STAR, CALIBRATION, RA=01H 36M 39.766S +/- 1", J2000 V = 14.10+/-0.1 ASTROMETRIC DEC=41D 22' 16.860" +/- 1", PLATE-ID=01JW Coordinate Source: GUIDE_STAR_CATALOG 5 REF4 STAR, CALIBRATION, RA=01H 36M 39.979S +/- 1", J2000 V = 14.72+/-0.1 ASTROMETRIC DEC=41D 23' 48.338" +/- 1", PLATE-ID=01JW Coordinate Source: GUIDE_STAR_CATALOG 6 REF5 STAR, CALIBRATION, RA=01H 37M 12.984S +/- 1", J2000 V = 11.06+/-0.1 ASTROMETRIC DEC=41D 24' 43.056" +/- 1", PLATE-ID=01JW Coordinate Source: GUIDE_STAR_CATALOG 7 REF6 STAR, CALIBRATION, RA=01H 36M 41.87S +/- 1", J2000 V = 13.95+/-0.1 ASTROMETRIC DEC=41D 20' 53.516" +/- 1", PLATE-ID=01JW Coordinate Source: GUIDE_STAR_CATALOG 8 VTT1 STAR, CALIBRATION, RA=01H 36M 41.350S +/- 1", J2000 V = 15.0 ASTROMETRIC DEC=41D 24' 6.70" +/- 1" Coordinate Source: Other_Source: DSS2 9 VTT2 STAR, CALIBRATION, RA=01H 36M 50.66S +/- 1", J2000 V = 15.0+/-0.1 ASTROMETRIC DEC=41D 23' 38.77" +/- 1" Coordinate Source: Other_Source: DSS2 10 VTT3 STAR, CALIBRATION, RA=01H 36M 45.10S +/- 1", J2000 V = 15.5+/-0.1 ASTROMETRIC DEC=41D 23' 45.140" +/- 1" Coordinate Source: Other_Source: DSS2 11 VTT4 STAR, CALIBRATION, RA=01H 36M 59.370S +/- 1", J2000 V = 15.5+/-0.1 ASTROMETRIC DEC=41D 26' 16.41" +/- 1" Coordinate Source: Other_Source: DSS2 12 VTT5 STAR, CALIBRATION, RA=01H 36M 44.950S +/- 1", J2000 V = 15.50+/-0.1 ASTROMETRIC DEC=41D 24' 21.410" +/- 1" Coordinate Source: Other_Source: DSS2 9971( 4) - 05/22/03 08:29 - [ 5] TARGET LIST Fixed Targets ------------------------------------------------------------------------------------------------------------------------------------ Tar| Target | Target | Target |Coord | Radial | Flux data No | Name | Description | Position |Eqnx | Vel. | ------------------------------------------------------------------------------------------------------------------------------------ 102 REF1A STAR, CALIBRATION, RA=01H 36M 57.120S +/- 1", J2000 V = 13.09+/-0.1 ASTROMETRIC DEC=41D 23' 42.144" +/- 1", PLATE-ID=01JW Coordinate Source: GUIDE_STAR_CATALOG 103 REF2A STAR, CALIBRATION, RA=01H 36M 50.568S +/- 1", J2000 V = 13.74 ASTROMETRIC DEC=41D 22' 37.560" +/- 1", PLATE-ID=01JW Coordinate Source: GUIDE_STAR_CATALOG 104 REF3A STAR, CALIBRATION, RA=01H 36M 39.766S +/- 1", J2000 V = 14.48+/-0.1 ASTROMETRIC DEC=41D 22' 16.860" +/- 1", PLATE-ID=01JW Coordinate Source: GUIDE_STAR_CATALOG 105 REF4A STAR, CALIBRATION, RA=01H 36M 39.979S +/- 1", J2000 V = 14.8+/-0.1 ASTROMETRIC DEC=41D 23' 48.338" +/- 1", PLATE-ID=01JW Coordinate Source: GUIDE_STAR_CATALOG 106 REF5A STAR, CALIBRATION, RA=01H 37M 12.984S +/- 1", J2000 V = 11.40+/-0.1 ASTROMETRIC DEC=41D 24' 43.056" +/- 1", PLATE-ID=01JW Coordinate Source: GUIDE_STAR_CATALOG 108 VTT1A STAR, CALIBRATION, RA=01H 36M 41.350S +/- 1", J2000 V = 14.62 ASTROMETRIC DEC=41D 24' 6.70" +/- 1" Coordinate Source: Other_Source: DSS2 111 VTT4A STAR, CALIBRATION, RA=01H 36M 59.370S +/- 1", J2000 V = 15.78+/-0.1 ASTROMETRIC DEC=41D 26' 16.41" +/- 1" Coordinate Source: Other_Source: DSS2 112 REF7 STAR, CALIBRATION, RA=01H 36M 59.225S +/- 1", J2000 V = 11.49+/-0.1 ASTROMETRIC DEC=41D 29' 28.680" +/- 1" Coordinate Source: GUIDE_STAR_CATALOG 113 VTT2A STAR, CALIBRATION, RA=01H 36M 50.41S +/- 1", J2000 V = 14.0+/-0.1 ASTROMETRIC DEC=41D 23' 32.56" +/- 1" Coordinate Source: Other_Source: DSS2 Epoch of Position RA proper motion (seconds of time/yr) DEC Proper Motion (arcsec/yr) Annual Parallax (arcsec) J2000 -0.0156 -0.381 0.0 9971( 4) - 05/22/03 08:29 - [ 6] Visit: 01 Visit Priority: Visit Requirements: SCHED 100% ORIENT 244D TO 244D BETWEEN 24-Jul-2003 AND 30-Jul-2003 On Hold Comments: Additional Comments: Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 10 UPS-AND FGS POS 1 F5ND 1 10 S POS TARG 42,-75 SEQ 10-220 NON-INT GS ACQ SCENARIO SINGLE ------------------------------------------------------------------------------------------------------------------------------------ 20 VTT2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 30 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 40 REF5A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 50 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 60 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 70 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 80 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 90 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 100 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 110 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 120 VTT2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 130 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 140 REF5A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 150 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 160 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 170 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 180 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 190 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 7] Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 200 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 210 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 220 VTT2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 8] Visit: 02 Visit Priority: Visit Requirements: SCHED 100% ORIENT 244D TO 244D AFTER 01 BY 2 D TO 3 D On Hold Comments: Additional Comments: Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 10 UPS-AND FGS POS 1 F5ND 1 10 S POS TARG 42,-75 SEQ 10-220 NON-INT GS ACQ SCENARIO SINGLE ------------------------------------------------------------------------------------------------------------------------------------ 20 VTT2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 30 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 40 REF5A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 50 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 60 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 70 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 80 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 90 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 100 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 110 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 120 VTT2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 130 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 140 REF5A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 150 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 160 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 170 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 180 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 190 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 9] Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 200 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 210 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 220 VTT2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 10] Visit: 03 Visit Priority: Visit Requirements: SCHED 100% ORIENT 244D TO 244D AFTER 02 BY 2 D TO 3 D On Hold Comments: Additional Comments: Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 10 UPS-AND FGS POS 1 F5ND 1 10 S POS TARG 42,-75 SEQ 10-220 NON-INT GS ACQ SCENARIO SINGLE ------------------------------------------------------------------------------------------------------------------------------------ 20 VTT2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 30 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 40 REF5A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 50 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 60 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 70 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 80 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 90 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 100 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 110 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 120 VTT2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 130 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 140 REF5A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 150 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 160 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 170 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 180 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 190 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 11] Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 200 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 210 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 220 VTT2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 12] Visit: 04 Visit Priority: Visit Requirements: SCHED 100% ORIENT 244D TO 244D AFTER 03 BY 2 D TO 3 D On Hold Comments: Additional Comments: Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 10 UPS-AND FGS POS 1 F5ND 1 10 S POS TARG 42,-75 SEQ 10-220 NON-INT GS ACQ SCENARIO SINGLE ------------------------------------------------------------------------------------------------------------------------------------ 20 VTT2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 30 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 40 REF5A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 50 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 60 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 70 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 80 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 90 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 100 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 110 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 120 VTT2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 130 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 140 REF5A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 150 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 160 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 170 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 180 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 190 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 13] Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 200 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 210 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 220 VTT2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 14] Visit: 05 Visit Priority: Visit Requirements: SCHED 100% ORIENT 244D TO 244D AFTER 04 BY 2 D TO 3 D On Hold Comments: Additional Comments: Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 10 UPS-AND FGS POS 1 F5ND 1 10 S POS TARG 42,-75 SEQ 10-220 NON-INT GS ACQ SCENARIO SINGLE ------------------------------------------------------------------------------------------------------------------------------------ 20 VTT2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 30 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 40 REF5A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 50 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 60 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 70 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 80 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 90 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 100 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 110 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 120 VTT2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 130 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 140 REF5A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 150 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 160 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 170 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 180 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 190 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 15] Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 200 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 210 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 220 VTT2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 16] Visit: 06 Visit Priority: Visit Requirements: SCHED 100% ORIENT 244D TO 244D AFTER 05 BY 2 D TO 3 D On Hold Comments: Additional Comments: Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 10 UPS-AND FGS POS 1 F5ND 1 10 S POS TARG 42,-75 SEQ 10-220 NON-INT GS ACQ SCENARIO SINGLE ------------------------------------------------------------------------------------------------------------------------------------ 20 VTT2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 30 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 40 REF5A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 50 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 60 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 70 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 80 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 90 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 100 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 110 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 120 VTT2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 130 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 140 REF5A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 150 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 160 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 170 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 180 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 190 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 17] Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 200 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 210 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 220 VTT2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 18] Visit: 07 Visit Priority: Visit Requirements: SCHED 100% ORIENT 200D TO 200D BETWEEN 24-Sep-2003 AND 28-Sep-2003 On Hold Comments: Additional Comments: Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 10 UPS-AND FGS POS 1 F5ND 1 6 S POS TARG -57,-26 SEQ 10-230 NON-INT GS ACQ SCENARIO SINGLE ------------------------------------------------------------------------------------------------------------------------------------ 20 VTT2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 30 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 40 REF7 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 50 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 60 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 70 UPS-AND FGS POS 1 F5ND 1 6 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 80 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 90 REF4A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 100 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 110 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 120 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 130 VTT2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 140 UPS-AND FGS POS 1 F5ND 1 6 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 150 REF7 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 160 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 170 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 190 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 200 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 19] Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 210 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 220 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 230 UPS-AND FGS POS 1 F5ND 1 6 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 20] Visit: 08 Visit Priority: Visit Requirements: SCHED 100% ORIENT 200D TO 200D AFTER 07 BY 2 D TO 3 D On Hold Comments: Additional Comments: Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 10 UPS-AND FGS POS 1 F5ND 1 6 S POS TARG -57,-26 SEQ 10-230 NON-INT GS ACQ SCENARIO SINGLE ------------------------------------------------------------------------------------------------------------------------------------ 20 VTT2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 30 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 40 REF7 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 50 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 60 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 70 UPS-AND FGS POS 1 F5ND 1 6 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 80 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 90 REF4A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 100 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 110 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 120 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 130 VTT2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 140 UPS-AND FGS POS 1 F5ND 1 6 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 150 REF7 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 160 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 170 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 190 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 200 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 21] Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 210 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 220 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 230 UPS-AND FGS POS 1 F5ND 1 6 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 22] Visit: 09 Visit Priority: Visit Requirements: SCHED 100% ORIENT 200D TO 200D AFTER 08 BY 2 D TO 3 D On Hold Comments: Additional Comments: Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 10 UPS-AND FGS POS 1 F5ND 1 6 S POS TARG -57,-26 SEQ 10-230 NON-INT GS ACQ SCENARIO SINGLE ------------------------------------------------------------------------------------------------------------------------------------ 20 VTT2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 30 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 40 REF7 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 50 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 60 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 70 UPS-AND FGS POS 1 F5ND 1 6 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 80 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 90 REF4A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 100 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 110 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 120 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 130 VTT2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 140 UPS-AND FGS POS 1 F5ND 1 6 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 150 REF7 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 160 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 170 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 190 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 200 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 23] Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 210 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 220 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 230 UPS-AND FGS POS 1 F5ND 1 6 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 24] Visit: 10 Visit Priority: Visit Requirements: SCHED 100% ORIENT 200D TO 200D AFTER 09 BY 2 D TO 3 D On Hold Comments: Additional Comments: Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 10 UPS-AND FGS POS 1 F5ND 1 6 S POS TARG -57,-26 SEQ 10-230 NON-INT GS ACQ SCENARIO SINGLE ------------------------------------------------------------------------------------------------------------------------------------ 20 VTT2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 30 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 40 REF7 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 50 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 60 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 70 UPS-AND FGS POS 1 F5ND 1 6 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 80 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 90 REF4A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 100 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 110 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 120 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 130 VTT2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 140 UPS-AND FGS POS 1 F5ND 1 6 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 150 REF7 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 160 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 170 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 190 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 200 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 25] Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 210 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 220 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 230 UPS-AND FGS POS 1 F5ND 1 6 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 26] Visit: 11 Visit Priority: Visit Requirements: SCHED 100% ORIENT 200D TO 200D AFTER 10 BY 2 D TO 3 D On Hold Comments: Additional Comments: Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 10 UPS-AND FGS POS 1 F5ND 1 6 S POS TARG -57,-26 SEQ 10-230 NON-INT GS ACQ SCENARIO SINGLE ------------------------------------------------------------------------------------------------------------------------------------ 20 VTT2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 30 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 40 REF7 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 50 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 60 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 70 UPS-AND FGS POS 1 F5ND 1 6 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 80 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 90 REF4A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 100 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 110 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 120 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 130 VTT2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 140 UPS-AND FGS POS 1 F5ND 1 6 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 150 REF7 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 160 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 170 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 190 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 200 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 27] Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 210 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 220 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 230 UPS-AND FGS POS 1 F5ND 1 6 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 28] Visit: 12 Visit Priority: Visit Requirements: SCHED 100% ORIENT 200D TO 200D AFTER 11 BY 2 D TO 3 D On Hold Comments: Additional Comments: Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 10 UPS-AND FGS POS 1 F5ND 1 6 S POS TARG -57,-26 SEQ 10-230 NON-INT GS ACQ SCENARIO SINGLE ------------------------------------------------------------------------------------------------------------------------------------ 20 VTT2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 30 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 40 REF7 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 50 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 60 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 70 UPS-AND FGS POS 1 F5ND 1 6 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 80 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 90 REF4A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 100 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 110 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 120 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 130 VTT2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 140 UPS-AND FGS POS 1 F5ND 1 6 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 150 REF7 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 160 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 170 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 190 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 200 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 29] Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 210 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 220 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 230 UPS-AND FGS POS 1 F5ND 1 6 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 30] Visit: 13 Visit Priority: Visit Requirements: SCHED 100% ORIENT 55D TO 55D BETWEEN 10-FEB-2004 AND 27-FEB-2004 On Hold Comments: Additional Comments: Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 10 UPS-AND FGS POS 1 F5ND 1 10 S POS TARG 0, 16 SEQ 10-220 NON-INT ------------------------------------------------------------------------------------------------------------------------------------ 20 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 30 REF5A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 40 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 50 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 60 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 70 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 80 REF4A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 90 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 100 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 110 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 120 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 130 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 140 REF5A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 150 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 160 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 170 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 180 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 190 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 200 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 31] Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 210 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 220 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 32] Visit: 14 Visit Priority: Visit Requirements: SCHED 100% ORIENT 55D TO 55D AFTER 13 BY 2 D TO 3 D On Hold Comments: Additional Comments: Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 10 UPS-AND FGS POS 1 F5ND 1 10 S POS TARG 0, 16 SEQ 10-220 NON-INT ------------------------------------------------------------------------------------------------------------------------------------ 20 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 30 REF5A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 40 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 50 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 60 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 70 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 80 REF4A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 90 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 100 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 110 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 120 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 130 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 140 REF5A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 150 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 160 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 170 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 180 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 190 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 200 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 33] Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 210 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 220 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 34] Visit: 15 Visit Priority: Visit Requirements: SCHED 100% ORIENT 55D TO 55D AFTER 14 BY 2 D TO 3 D On Hold Comments: Additional Comments: Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 10 UPS-AND FGS POS 1 F5ND 1 10 S POS TARG 0, 16 SEQ 10-220 NON-INT ------------------------------------------------------------------------------------------------------------------------------------ 20 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 30 REF5A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 40 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 50 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 60 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 70 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 80 REF4A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 90 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 100 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 110 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 120 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 130 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 140 REF5A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 150 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 160 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 170 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 180 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 190 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 200 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 35] Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 210 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 220 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 36] Visit: 16 Visit Priority: Visit Requirements: SCHED 100% ORIENT 55D TO 55D AFTER 15 BY 2 D TO 3 D On Hold Comments: Additional Comments: Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 10 UPS-AND FGS POS 1 F5ND 1 10 S POS TARG 0, 16 SEQ 10-220 NON-INT ------------------------------------------------------------------------------------------------------------------------------------ 20 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 30 REF5A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 40 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 50 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 60 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 70 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 80 REF4A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 90 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 100 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 110 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 120 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 130 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 140 REF5A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 150 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 160 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 170 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 180 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 190 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 200 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 37] Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 210 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 220 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 38] Visit: 17 Visit Priority: Visit Requirements: SCHED 100% ORIENT 55D TO 55D AFTER 16 BY 2 D TO 3 D On Hold Comments: Additional Comments: Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 10 UPS-AND FGS POS 1 F5ND 1 10 S POS TARG 0, 16 SEQ 10-220 NON-INT ------------------------------------------------------------------------------------------------------------------------------------ 20 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 30 REF5A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 40 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 50 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 60 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 70 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 80 REF4A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 90 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 100 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 110 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 120 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 130 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 140 REF5A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 150 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 160 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 170 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 180 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 190 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 200 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 39] Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 210 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 220 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 40] Visit: 18 Visit Priority: Visit Requirements: SCHED 100% ORIENT 55D TO 55D AFTER 17 BY 2 D TO 3 D On Hold Comments: Additional Comments: Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 10 UPS-AND FGS POS 1 F5ND 1 10 S POS TARG 0, 16 SEQ 10-220 NON-INT ------------------------------------------------------------------------------------------------------------------------------------ 20 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 30 REF5A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 40 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 50 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 60 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 70 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 80 REF4A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 90 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 100 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 110 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 120 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 130 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 140 REF5A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 150 VTT4A FGS POS 1 F583W 1 30 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 160 REF2A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 170 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 180 VTT1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 190 REF3A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 200 REF6 FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 41] Exposures ------------------------------------------------------------------------------------------------------------------------------------ Exposure| Target |Instr | Oper. | Aper |Spectral|Central| Optional |Num| Time | Special Number | Name |Config| Mode |or FOV |Element |Waveln.| Parameters |Exp| | Requirements ------------------------------------------------------------------------------------------------------------------------------------ 210 REF1A FGS POS 1 F583W 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 220 UPS-AND FGS POS 1 F5ND 1 10 S SAME POS AS 10 ------------------------------------------------------------------------------------------------------------------------------------ 9971( 4) - 05/22/03 08:29 - [ 42] Summary Form for Proposal 9971 Item Used in this proposal ------------------------------------------------------------------------------------------------------------------------------------ Apertures 1 ------------------------------------------------------------------------------------------------------------------------------------ Configurations FGS ------------------------------------------------------------------------------------------------------------------------------------ Opmodes POS ------------------------------------------------------------------------------------------------------------------------------------ Proposal Category GO ------------------------------------------------------------------------------------------------------------------------------------ Special Requirements SCHED 100% ORIENT 244D TO 244D BETWEEN 24-Jul-2003 AND 30-Jul-2003 POS TARG 42,-75 SEQ 10-220 NON-INT GS ACQ SCENARIO SINGLE SAME POS AS 10 SCHED 100% ORIENT 244D TO 244D AFTER 01 BY 2 D TO 3 D SCHED 100% ORIENT 244D TO 244D AFTER 02 BY 2 D TO 3 D SCHED 100% ORIENT 244D TO 244D AFTER 03 BY 2 D TO 3 D SCHED 100% ORIENT 244D TO 244D AFTER 04 BY 2 D TO 3 D SCHED 100% ORIENT 244D TO 244D AFTER 05 BY 2 D TO 3 D SCHED 100% ORIENT 200D TO 200D BETWEEN 24-Sep-2003 AND 28-Sep-2003 POS TARG -57,-26 SEQ 10-230 NON-INT GS ACQ SCENARIO SINGLE SCHED 100% ORIENT 200D TO 200D AFTER 07 BY 2 D TO 3 D SCHED 100% ORIENT 200D TO 200D AFTER 08 BY 2 D TO 3 D SCHED 100% ORIENT 200D TO 200D AFTER 09 BY 2 D TO 3 D SCHED 100% ORIENT 200D TO 200D AFTER 10 BY 2 D TO 3 D SCHED 100% ORIENT 200D TO 200D AFTER 11 BY 2 D TO 3 D SCHED 100% ORIENT 55D TO 55D BETWEEN 10-FEB-2004 AND 27-FEB-2004 POS TARG 0, 16 SEQ 10-220 NON-INT SCHED 100% ORIENT 55D TO 55D AFTER 13 BY 2 D TO 3 D SCHED 100% ORIENT 55D TO 55D AFTER 14 BY 2 D TO 3 D SCHED 100% ORIENT 55D TO 55D AFTER 15 BY 2 D TO 3 D SCHED 100% ORIENT 55D TO 55D AFTER 16 BY 2 D TO 3 D SCHED 100% ORIENT 55D TO 55D AFTER 17 BY 2 D TO 3 D ------------------------------------------------------------------------------------------------------------------------------------ Spectral Elements F5ND F583W ------------------------------------------------------------------------------------------------------------------------------------ Target Names UPS-AND VTT2A REF1A REF5A VTT4A VTT1A REF3A REF6 REF2A REF7 REF4A ------------------------------------------------------------------------------------------------------------------------------------