Overview
WFC3 Calibration Plans
Initial calibration of WFC3 has taken place on the ground in simulated orbital conditions. Shortly after launch, observations will be used to assess the on-orbit performance of the camera during a period called SMOV. As with the other HST instruments, calibrations will be periodically updated through new observations campaigns every year. The results of these calibration programs will be documented as they become available via Instrument Science Reports on the WFC3 ISR webpage.
A summary of HST calibration in the current cycle, and a comparison with prior cycles, may be found on the HST Calibration Plan webpage. Statistics on WFC3 usage for science programs may be found on the Instrument Usage webpage.
Cycle 28 Calibration
11/2020-10/2021 (12 months)
In Cycle 28 the WFC3 team will carry out an extended calibration program to monitor the behavior of the UVIS and IR channels and to provide the best calibration data for scientific programs.
The Cycle 28 calibration plan was designed to:
- Maintain and update the standard reference files (biases, darks, linearity, CTE traps, UVIS anomalous QE pixels, post-flash)
- Monitor the health of the instrument (throughput, gain, hysteresis, bad/hot pixels, sink pixels, CTE decline, stability of the post-flash LED, filter transmission, state of the CSM, number of IR blobs, wavelength and flux stability of the grisms)
- Support new initiatives and obtain supplemental (non-routine) calibration data
In this cycle, the IR Grism Flux Monitor (program 16408) has been modified to:
- Quantify sensitivity losses in the IR grisms by supplementing the annual GD153 data with two additional WD standards
Three new calibration programs will supplement the standard monitoring. These programs (16039, 16040, 16041) were designed to:
- Check whether the IR filters are losing sensitivity, or if losses are limited to the IR grisms
-
Recheck the optimal background (post-flash) level, as CTE losses continue to grow
-
Measure the impact of CTE on very faint stars
Program ID | Description |
---|---|
16414 | WFC3 UVIS Anneal |
16393 | WFC3 UVIS Bowtie Monitor |
16394 | WFC3 UVIS CCD Daily Monitor Part 1 |
16395 | WFC3 UVIS CCD Daily Monitor Part 2 |
16396 | WFC3 UVIS CCD Daily Monitor Part 3 |
16397 | WFC3 UVIS CCD Unflashed (CTE) Monitor |
16398 | WFC3 UVIS Post-flash Monitor |
16399 | WFC3 UVIS CCD Gain Stability |
16400 | WFC3 UVIS CTI Monitor (EPER) |
16401 | WFC3 UVIS CTE Monitor (Star Cluster) |
16402 | WFC3 UVIS Traps with Charge Injection |
16403 | WFC3 IR Dark Monitor |
16404 | WFC3 IR Linearity Monitor |
16405 | WFC3 IR Gain Monitor |
16406 | WFC3 UVIS Shutter Monitoring |
16415 | WFC3 UVIS and IR Photometry |
16416 | WFC3 UVIS Time Dependent Sensitivity |
16407 | WFC3 IR Grism Wavelength Calibration |
16408 | WFC3 IR Grism Flux Calibration |
16409 | WFC3 UVIS Pixel-to-Pixel QE Variations via Int Flats |
16410 | WFC3 UVIS Internal Flats |
16411 | WFC3 IR Internal Flats |
16412 | WFC3 CSM Monitor with Earth Flats |
16413 | WFC3 Astrometric Scale Monitoring |
16439 | WFC3 IR Time Dependent Sensitivity |
16440 | WFC3 UVIS CTE: A Direct Approach to Model Pinning |
16441 | WFC3 UVIS: CTE Effects for the Faintest Point Sources |
Cycle 27 Calibration
11/2019 - 10/2020 (12 months)
In Cycle 27 the WFC3 team will carry out an extended calibration program to monitor the behavior of the UVIS and IR channels and to provide the best calibration data for scientific programs.
The Cycle 27 calibration plan was designed to:
• Maintain and update the standard reference files (biases, darks, linearity, CTE traps, UVIS anomalous QE pixels, post-flash)
• Monitor the health of the instrument (throughput, gain, hysteresis, bad/hot pixels, sink pixels, CTE decline, stability of the post-flash LED, filter transmission, state of the CSM, number of IR blobs, wavelength and flux stability of the grisms)
• Support new initiatives and obtain supplemental (non-routine) calibration data
In this cycle, two standard monitoring programs have been restructured from Cycle 26. These programs (16021, 16030) were designed to:
• Quantify losses in the UVIS sensitivity using spatial scans (previously called ‘UVIS Contamination Monitor)
• Monitor the ‘UVIS and IR Photometric Calibration’ via staring mode observations of HST standards
Five new calibration programs will supplement the standard monitoring. These programs (16020, 16022, 16023, 16029, 16031) were designed to:
• Measure the stability of the tungsten lamp output immediately after turn-on
• Refine the UVIS grism wavelength calibration across the entire detector with better 2D sampling
• Finalize the flux calibration of the UVIS grism with similar spatial sampling as for the wavelength calibration
• Recheck the optimal UVIS background level to mitigate CTE losses
• Check for time dependent sensitivity in the IR detector grisms and filters
Proposal ID | Description |
---|---|
15712 | WFC3 UVIS Anneal |
15713 | WFC3 UVIS Bowtie Monitor |
15714 | WFC3 UVIS CCD Daily Monitor (Darks and Biases) Part 1 |
15715 | WFC3 UVIS CCD Daily Monitor (Darks and Biases) Part 2 |
15716 | WFC3 UVIS CCD Daily Monitor (Darks and Biases) Part 3 |
15717 | WFC3 UVIS CCD Unflashed (CTE) Monitor |
15718 | WFC3 UVIS Post-flash Monitor |
15719 | WFC3 UVIS CCD Gain Stability |
15720 | WFC3 UVIS CTI Monitor (EPER) |
15721 | WFC3 UVIS CTE Monitor (star cluster) |
15722 | WFC3 Characterization of UVIS traps with Charge Injection |
15723 | WFC3 IR Dark Monitor |
15724 | WFC3 IR Linearity Monitor |
15725 | WFC3 IR Gain Monitor |
15726 | WFC3 UVIS Shutter Monitoring |
15727 | WFC3 IR Grism Wavelength Calibration |
15728 | WFC3 IR Grism Flux/trace Calibration |
15729 | WFC3 UVIS Pixel-to-Pixel QE Variations via Internal Flats |
15730 | WFC3 UVIS Internal Flats |
15731 | WFC3 IR Internal Flats |
15732 | WFC3 CSM Monitor with Earth Flats |
15733 | WFC3 Astrometric Scale Monitoring |
16020 | WFC3 Tungsten Lamp Warmup |
16021 | WFC3 UVIS Time Dependent Sensitivity |
16022 | WFC3 UVIS Grism Wavelength Calibration |
16023 | WFC3 UVIS Grism Flux Calibration |
16029 | WFC3 UVIS Background Check |
16030 | WFC3 UVIS & IR Photometry Monitor |
Cycle 26 Calibration
11/2018 - 10/2019 (12 months)
In Cycle 26 the WFC3 team will carry out an extended calibration program to monitor the behavior of the UVIS and IR channels and to provide the best calibration data for scientific programs.
Cycle 26 calibration plan was designed to:
- Maintain and update the standard reference files (biases, darks, linearity, CTE traps, UVIS anomalous QE pixels, post-flash)
- Monitor the health of the instrument (throughput, gain, hysteresis, bad/hot pixels, sink pixels, CTE decline, stability of the post-flash LED, filter transmission, state of the CSM, number of IR blobs, wavelength and flux stability of the grisms)
- Support new initiatives and obtain supplemental (non-routine) calibration data
In this cycle, two new calibration programs will supplement the standard monitoring data. These programs were designed to:
- Cross-calibrate the HST focus values derived from the OTA Focus monitor (based on UVIS/F410M observations) with the focus values derived empirically from the WFC3/UVIS PSF database, which has many more F606W observations
- Characterize the decay of IR persistence at short time-scales (t <300 sec), where the observed residual signal deviates from the current power-law model
Program ID | Description |
---|---|
15567 | WFC3 UVIS Anneal |
15568 | WFC3 UVIS Bowtie Monitor |
15569 | WFC3 UVIS CCD Daily Monitor (Darks and Biases) Part 1 |
15570 | WFC3 UVIS CCD Daily Monitor (Darks and Biases) Part 2 |
15571 | WFC3 UVIS CCD Daily Monitor (Darks and Biases) Part 3 |
15572 | WFC3 UVIS CCD Unflashed (CTE) Monitor |
15573 | WFC3 UVIS Post-flash Monitor |
15574 | WFC3 UVIS CCD Gain Stability |
15575 | WFC3 UVIS CTI Monitor (EPER) |
15576 | WFC3 UVIS CTE Monitor (star cluster) |
15577 | WFC3 Characterization of UVIS traps with Charge Injection |
15578 | WFC3 IR Dark Monitor |
15579 | WFC3 IR Linearity Monitor |
15580 | WFC3 IR Gain Monitor |
15581 | WFC3 Short-term IR Persistence |
15582 | WFC3 UVIS & IR Photometry |
15583 | WFC3 UVIS Contamination Monitor (staring and scans) |
15584 | WFC3 UVIS Shutter Monitoring |
15585 | WFC3 Focus Cross-Calibration |
15586 | WFC3 IR Grism Wavelength Calibration |
15587 | WFC3 IR Grism Flux/trace Calibration |
15588 | WFC3 UVIS Grism Wavelength Calibration |
15589 | WFC3 UVIS Pixel-to-Pixel QE Variations via Internal Flats |
15590 | WFC3 UVIS Internal Flats |
15591 | WFC3 IR Internal Flats |
15592 | WFC3 CSM Monitor with Earth Flats |
15593 | WFC3 Astrometric Scale Monitoring |
Cycle 25 Calibration
11/2017 - 10/2018 (12 months)
In Cycle 25 the WFC3 team will carry out an extended calibration program to monitor the behavior of the UVIS and IR channels and to provide the best calibration data for scientific programs.
Cycle 25 calibration plan was designed to:
- maintain and update the standard reference files (biases, darks, linearity, CTE traps, UVIS anomalous QE pixels, post-flash)
- monitor the health of the instrument (throughput, gain, hysteresis, bad/hot pixels, sink pixels, CTE decline, stability of the post-flash LED, filter transmission, state of the CSM, number of IR blobs, wavelength and flux stability of grisms)
- improve the precision of the UVIS contamination monitor using scanned observations of of photometric standards
- quantify color terms for the UVIS filters and recheck the photometric calibration at the center of the detector
- test a strategy to mitigate IR persistence using the calibration lamps to fill charge traps prior to obtaining science observations
Program ID | Description |
---|---|
14978 | WFC3 UVIS Anneal |
14979 | WFC3 UVIS Bowtie Monitor |
14980 | WFC3 UVIS CCD Daily Monitor (darks & biases) (Part 1) |
14981 | WFC3 UVIS CCD Daily Monitor (darks & biases) (Part 2) |
14982 | WFC3 UVIS CCD Daily Monitor (darks & biases) (Part 3) |
14983 | WFC3 UVIS CCD Un-flashed Monitor |
14984 | WFC3 UVIS Post-flash Monitor |
14985 | WFC3 UVIS CCD Gain Stability |
14986 | WFC3 IR Dark Monitor |
14987 | WFC3 IR Linearity Monitor |
14988 | WFC3 IR Gain Monitor |
14989 | WFC3 UVIS CTI monitor (EPER) |
14990 | WFC3 UVIS CTE monitor (star cluster) |
14991 | WFC3 Characterization of UVIS traps with CI |
14992 | WFC3 UVIS & IR photometry |
14993 | WFC3 IR grisms wavelength calibration |
14994 | WFC3 IR grisms flux/trace calibration |
14995 | WFC3 UVIS grism wavelength calibration |
14996 | WFC3 UVIS Pixel-to-Pixel QE Variations via Internal Flats |
14997 | WFC3 UVIS Internal Flats |
14998 | WFC3 IR Internal Flats |
14999 | WFC3 CSM monitor with Earth Flats |
15000 | WFC3 Astrometric scale monitoring |
15397 | UVIS shutter monitoring |
15398 | UVIS contamination monitor (staring and scans) |
15399 | UVIS Supplemental Photometry: Color Terms & Revisiting M512C |
15400 | Mitigating Persistence for Time-Series Observations |
Cycle 24 Calibration
11/2016 - 10/2017 (12 months)
During Cycle 24 the WFC3 team will carry on an extended calibration program designed to measure and monitor the behavior of both the UVIS and IR channels of WFC3 and to provide the best calibration data for the approved scientific programs.
Cycle 24 calibration plan was designed to:
- maintain and update the standard reference files (biases, darks, linearity, CTE traps, UVIS anomalous QE pixels, post-flash)
- monitor the health of the instrument (throughput, gain, hysteresis, bad/hot pixels, sink pixels, CTE decline, stability of the post-flash LED, filter transmission, state of the CSM, number of IR blobs, wavelength and flux stability of grisms)
- test the precision of the IR count rate non-linearity correction for faint targets and determine whether a wavelength-dependent correction is required
- improve the precision of the UVIS contamination monitor by making use of spatially scanned observations of photometric standards
- re-evaluate the 2013 UVIS pixel-based CTE model and verify that the recommended post-flash level has not changed
Program ID | Description |
---|---|
14529 | WFC3 UVIS Anneal |
14530 | UVIS Bowtie Monitor |
14531 | WFC3 UVIS Daily Monitor A |
14532 | WFC3 UVIS Daily Monitor B |
14533 | WFC3 UVIS Daily Monitor C |
14534 | WFC3 UVIS Unflashed Monitor |
14535 | UVIS Post-Flash monitor |
14536 | WFC3 UVIS CCD Gain Stability |
14537 | IR Dark Monitor |
14538 | WFC3 IR Linearity Monitor |
14539 | WFC3 IR Gain Monitor |
14540 | UVIS CTI Monitor (EPER) |
14541 | WFC3 UVIS CTE Monitor (Star cluster) |
14542 | Characterization of UVIS traps with CI |
14543 | WFC3 IR grism Wavelength calibration |
14544 | WFC3 IR grism flux/trace calibration |
14545 | WFC3 UVIS grism Wavelength calibration |
14546 | UVIS Pixel-to-Pixel QE Variations via Internal Flats |
14547 | UVIS internal Flats |
14548 | IR Internal Flats |
14549 | CSM Monitor with Earth Flats |
14550 | Astrometry Monitoring |
14815 | UVIS Contamination Monitor |
14868 | Improved Precision, Wavelength Dependence of the IR Count-Rate Non-linearity |
14870 | IR Zeropoint Linearity |
14871 | Improving the CALSPEC Model for GRW+70D5824 |
14878 | UVIS Contamination using Spatial scans |
14879 | UVIS Sink Pixel Map Update |
14880 | UVIS CTE Model Re-Characterization |
14881 | UVIS CTE Pixel-Based Model Evaluation |
14882 | UVIS Shutter Monitoring |
14883 | WFC3 UVIS & IR Photometry |
Cycle 23 Calibration
11/2015 - 10/2016 (12 months)
During Cycle 23 the WFC3 team will carry on an extended calibration program designed to measure and monitor the behavior of both the UVIS and IR channels of WFC3 and to provide the best calibration data for the approved scientific programs.
Program ID | Description |
---|---|
14366 | WFC3 UVIS Anneal |
14367 | UVIS Bowtie Monitor |
14368 | WFC3 UVIS Daily Monitor A |
14369 | WFC3 UVIS Daily Monitor B |
14370 | WFC3 UVIS Daily Monitor C |
14371 | WFC3 UVIS Unflashed Monitor |
14372 | UVIS post-flash monitor |
14373 | WFC3 UVIS CCD Gain Stability |
14374 | IR Dark Monitor |
14375 | WFC3 IR Linearity Monitor |
14376 | WFC3 IR Gain Monitor |
14377 | UVIS CTI Monitor (EPER) |
14378 | WFC3 UVIS CTE Monitor (Star cluster) |
14379 | WFC3 UVIS Traps with CI |
14380 | WFC3 IR Persistence: Amplitude Variations |
14381 | WFC3 IR Persistence: Improve the Position Dependent Model |
14382 | WFC3/UVIS contamination and stability monitor |
14383 | WFC3 UVIS Shutter Characterization |
14384 | WFC3 UVIS & IR Photometry Zero Points |
14385 | IR grisms: wavelength calibration |
14386 | IR grisms: trace and flux calibration |
14387 | WFC3 UVIS Grism wavelength Calibration Stability |
14388 | WFC3 -First Grism Order Calibration in IR Grisms |
14389 | WFC3 UVIS Pixel variations via int-flat monitor |
14390 | UVIS Internal flats |
14391 | IR internal flats |
14392 | WFC3 CSM monitor Earth Flats |
14393 | WFC3 Astrometric Calibration of all remaining UVIS filters |
14394 | WFC3 Time Dependence of X-CTE & Astrometry |
Cycle 22 Calibration
11/2014 - 10/2015 (12 months)
During Cycle 22 the WFC3 team will carry on an extended calibration program designed to measure and monitor the behavior of both the UVIS and IR channels of WFC3 and to provide the best calibration data for the approved scientific programs.
Program ID | Description |
---|---|
14000 | UVIS Anneal |
14001 | UVIS Bowtie monitor |
14002 | UVIS Daily Monitor (a) |
14003 | UVIS Daily Monitor (b) |
14004 | UVIS Daily Monitor (c) |
14005 | UVIS Unflashed Monitor |
14006 | UVIS Post-Flash Monitor |
14007 | UVIS CCD Gain Stability |
14008 | IR Dark Monitor |
14009 | IR Linearity Monitor |
14010 | IR Gain Monitor |
14011 | UVIS CTI Monitor (EPER) |
14012 | UVIS CTE Monitor (Star cluster) |
14013 | UVIS CTE in subarrays |
14014 | UVIS Traps with CI |
14015 | Refining IR Persistence Model |
14016 | Short term IR Persistence |
14017 | Persistence after Worst Actors |
14018 | UVIS Contam Monitor |
14019 | UVIS Shutter Characterization |
14020 | Photometric Repeatibility |
14021 | UVIS & IR Photometry Zero Points |
14022 | IR Observations of Red CALSPEC Stars |
14023 | IR Grism wavelength Calibration stability |
14024 | IR Grisms flux and trace calibration stability |
14025 | UVIS Grism wavelength Calibration stability |
14026 | UVIS Grisms flux and trace calibration stability |
14027 | UVIS Pixel variations via int-flat monitor |
14028 | UVIS Internal Flats |
14029 | IR Internal Flats |
14030 | CSM monitor Earth Flats |
14031 | Astrometric Validation of UVIS Filters |
13929 | High precision calibration of UVIS Geometric distortion |
Cycle 21 Calibration
11/2013 - 10/2014 (12 months)
During Cycle 21 the WFC3 team will carry on an extended calibration program designed to measure and monitor the behavior of both the UVIS and IR channels of WFC3 and to provide the best calibration data for the approved scientific programs.
Program ID | Description |
---|---|
13554 | UVIS Anneal |
13555 | UVIS Bowtie Monitor |
13556 | UVIS CCD Daily Monitor A |
13557 | UVIS CCD Daily Monitor B |
13558 | UVIS CCD Daily Monitor C |
13559 | UVIS CCD un-flashed Monitor |
13560 | UVIS post-flash Monitor |
13561 | UVIS CCD Gain Stability |
13562 | IR Dark Monitor |
13563 | IR Linearity Monitor |
13564 | IR Gain Monitor |
13565 | UVIS CTI Monitor (EPER) |
13566 | UVIS CTE Monitor (star cluster) |
13567 | CTE Characterization with post-flashed Darks |
13568 | Charatcerizatopm of the charge-level Dependence of CTE Losses |
13569 | Characterization of UVIS Traps with CI |
13570 | UVIS & IR Geometric Distortion |
13571 | High Precision Astrometry |
13572 | IR Persistence Model Tests |
13573 | Trapping Mitigation in Spatial Scan Observations of Exosolar Planets |
13574 | WFC3 Contamination & Stability Monitor |
13575 | WFC3 UVIS & IR Photometry |
13576 | IR Grisms: Cross Check Sensitivity Function of Hot and Cool Stars |
13577 | UVIS Grisms: Flux Calibration |
13578 | UVIS Grisms: Wavelength Calibration |
13579 | IR Grisms: Flux Calibration |
13580 | IR Grisms: Wavelength Calibration |
13581 | IR Grisms: Sky Characterization |
13582 | Calibration of the IR Grism Wavelength ZPs |
13583 | UV Flats Spatial Scan |
13584 | UV Flat Field Validation |
13585 | CCD Anomalous QE Pixels |
13586 | UVIS Internal Flats |
13587 | IR Internal Flats |
13588 | CSM Monitor with Earth Flats |
Cycle 20 Calibration
11/05/2012 - 11/04/2013 (12 months)
During Cycle 20 the WFC3 team will carry on an extended calibration program designed to measure and monitor the behavior of both the UVIS and IR channels of WFC3 and to provide the best calibration data for the approved scientific programs.
Program ID | Description |
---|---|
13071 | UVIS Anneal |
13072 | UVIS Bowtie Monitor |
13073 | UVIS CCD Daily Monitor A |
13074 | UVIS CCD Daily Monitor B |
13075 | UVIS CCD Daily Monitor C |
13076 | UVIS CCD Daily Monitor D |
13168 | UVIS CCD Gain Stability |
13078 | UVIS Post-Flash Monitor |
13077 | IR Dark Monitor |
13079 | IR Linearity Monitor |
13080 | IR Gain Monitor |
13081 | Guard Dark for MCT Programs |
13082 | UVIS CTI Monitor (EPER) |
13083 | UVIS CTE Monitor (star clusters) |
13084 | Characterization of UVIS Traps with CI |
13085 | Line 10 CI Bias |
13086 | IR Persistance Behaviours as Function of Saturation Time |
13087 | IR Persistence Model Tests |
13088 | WFC3 Contamination & Stability Monitor |
13089 | WFC3 UVIS & IR Photometry |
13090 | UVIS Grism: Flux Calibratoin |
13091 | UVIS Grism: Wavelength Calibration |
13092 | IR Grisms: Flux Calibration |
13093 | IR Grisms: Wavelength Calibration |
13094 | IR Grism -1 Order Calibration |
13095 | UVIS L-Flat via Spatial Scans |
13096 | UVIS Flat Field Validation |
13169 | CCD Anomalous QE pixels |
13097 | UVIS Internal Flats |
13098 | IR Internal Flats |
13099 | IR Earth Flats |
13100 | UVIS & IR Geometric Distortion |
13101 | High Precision Astrometry |
Cycle 19 Calibration
10/01/2011 - 09/30/2012 (12 months)
During Cycle 19 the WFC3 team will carry on an extended calibration program designed to measure and monitor the behavior of both the UVIS and IR channels of WFC3 and to provide the best calibration data for the approved scientific programs.
Program ID | Description |
---|---|
12687 | UVIS Anneal |
12688 | UVIS Bowtie Monitor |
12689 | UVIS CCD Daily Monitor |
12690 | UVIS CCD Gain Stability |
12691 | UVIS CTI Monitor (EPER) |
12692 | UVIS CTE Monitor (Star Clusters) |
12693 | UVIS Charge Injection |
12694 | IR Persistence Strength |
12695 | IR Dark Monitor |
12696 | IR Linearity Monitor |
12697 | IR Gain Monitor |
12698 | WFC3 Contamination & Stability Monitor |
12699 | WFC3 Photometric Calibration & Calibration Flux Ladder |
12700 | Extending the Range & Precision of the Count Rate non Linearity |
12701 | WFC3 PSF Wings |
12702 | IR Grisms: Flux/Trace Calibration & Stability |
12703 | IR Grisms: Wavelength Calibration & Stability |
12704 | UVIS Grism: Flux Calibration |
12705 | UVIS Grism: Wavelength Calibration & Stability |
12706 | UVIS Flare Wavelength Dependence |
12707 | UVIS Spatial Sensitivity |
12708 | IR Spatial Sensitivity |
12709 | UVIS & IR Moonlit Flats |
12710 | UVIS Bright Earth Flats |
12711 | UVIS Internal Flats |
12712 | IR Internal Flats |
12713 | Spatial Scanned L-flat Validation Pathfinder |
12714 | UVIS & IR Geometric Distortion |
Cycle 18 Calibration
Cycle 17 Calibration
SMOV Plans
Servicing Mission Orbital Verification (SMOV) will take place shortly after the installation of WFC3 on HST during Servicing Mission 4. Below is a list of the planned tests to be executed to verify the performance of the instrument.
Program ID | Description |
---|---|
11357 | Load and Dump On-Board Memory |
11358 | Science Data Buffer Check |
11419 | UVIS Detector Functional Test |
11420 | IR Detector Functional Test |
11421 | Channel Select Mechanism Test |
11422 | SOFA Test |
11423 | IR FSM Test |
11424 | UVIS Initial Alignment |
11425 | IR Initial Alignment |
11426 | UVIS SMOV Contamination Monitor |
11427 | UVIS Shutter Test |
11428 | D2 Calibration Lamp Test |
11431 | UVIS Hot Pixel Anneal |
11432 | UVIS Internal Flats |
11433 | IR Internal Flats |
11434 | UVIS Fine Alignment |
11435 | IR Fine Alignment |
11436 | UVIS Image Quality |
11437 | IR Image Quality |
11438 | UVIS PSF Wings |
11439 | IR PSF Wings |
11440 | UVIS Pointing Stability |
11441 | IR Pointing Stability |
11442 | FGS-UVIS Alignment |
11443 | FGS-IR Alignment |
11444 | UVIS Plate Scale |
11445 | IR Plate Scale |
11446 | UVIS Dark Current, Noise, Background |
11447 | IR Dark Current, Noise, Background |
11448 | UVIS SAA Passage |
11449 | IR SAA Passage |
11450 | UVIS Photometric Zero Points |
11451 | IR Photometric Zero Points |
11452 | UVIS Flat Field Uniformity |
11453 | IR Flat Field Uniformity |
11454 | Activation Test |
11529 | UVIS Tungsten Lamp Cross Check |
11543 | IR Tungsten Lamp Cross Check |
11549 | UVIS and IR Pointing Stability |
11552 | Characterization of the WFC3 IR Grisms |
11798 | UVIS PSF Core Modulation |
11808 | UVIS Bowtie Monitor |
Ground Testing
WFC3 has undergone several iterations of fully integrated instrument testing. This testing took place at Goddard Space Flight Center (GSFC). During thermal vacuum (TV) testing, reference file data are collected and the instrument is characterized and calibrated. The first two TV sessions took place in the winter of 2004 and spring of 2007. TV3 testing is scheduled for early spring of 2008. The links below connect to pages giving the results from the various TV campaigns.
(Up to date calibration information is located in Howard Bushouse's Calibration Plan webpage. This page contains links to the science calibration test plan, SMS spreadsheets, and other associated documentation.)
TV Supporting Documents
- Castle ETC, V1.8 (18.8 MB)
- Castle ETC Manual (1.1MB)
- OS (Castle) Input Spreadsheet (23KB)
- SMS Input Spreadsheet, Version 2 (Nov '06) (38KB)
- Old versions of input spreadsheets.
Side Switch Contingency Plan
WFC3 Side Switch Servicing Mission Orbital Verification (SS SMOV) is a contingency plan for a WFC3 re-commissioning on Side 1, following a side switch.
Program ID | Description |
---|---|
13200 | WFC3 SS Activation Test |
13201 | WFC3 SS Science Data Buffer |
13202 | WFC3 SS UVIS Detector Functional |
13203 | WFC3 SS IR Detector Functional |
13204 | WFC3 SS CSM Test |
13205 | WFC3 SS UVIS SOFA Test |
13206 | WFC3 SS UVIS Spare Tungsten Lamp |
13207 | WFC3 SS IR FSM Test |
13208 | WFC3 SS IR Spare Tungsten Lamp |
13209 | WFC3 SS UVIS Contamination Monitor |
13210 | WFC3 SS UVIS Shutter Test |
13211 | WFC3 SS D2 Cal Lamp Test |
13212 | WFC3 SS UVIS Internal Flats |
13213 | WFC3 SS IR Internal Flats |
13214 | WFC3 SS UVIS Image Quality |
13215 | WFC3 SS IR Image Quality |
13216 | WFC3 SS UVIS PSF Wings |
13217 | WFC3 SS IR PSF Wings |
13218 | WFC3 SS FGS-UVIS Update |
13219 | WFC3 SS FGS-IR Update |
13220 | WFC3 SS UVIS Phot Zero Points |
13221 | WFC3 SS IR Phot Zero Points |
13222 | WFC3 SS UVIS Flat Fields Uniformity |
13223 | WFC3 SS IR Flat Field Uniformity |
13224 | WFC3 SS UVIS PSF Core Modulation |
13225 | WFC3 SS Post Flash Check |
13226 | WFC3 SS UVIS Fine Alignment |
13227 | WFC3 SS IR Fine Alignment |